Table of Contents

PitchRateVariesWithTime

https://bladednextgen.dnv.com/schema/0.4.1/Components/PitchSystem/PitchController/PitchSafetySystem/PitchRateVariesWithTime.json

A safety system where the pitch system will adjust its rate dependent on the time after which the safety system has been triggered.

  • PitchSafetySystemType: string = RateVariesWithTime
  • AlwaysUseBackupPower: boolean
  • TimeVsRate: array[object (RateVsTime)]

A type of PitchSafetySystem

Properties

AlwaysUseBackupPower: boolean, optional

Backup power is normally only used in a grid loss. If true, this will trigger a switch to backup power torque limits in all safety system pitch action events.

default = False

PitchSafetySystemType: string

Defines the specific type of PitchSafetySystem model in use. For a RateVariesWithTime object, this must always be set to a value of RateVariesWithTime.

TimeVsRate: array[ object (RateVsTime) ]

A look-up table of the rate versus the time after the safety system has been triggered.