TransducerFaultsLength coming soon
https://bladednextgen.dnv.com/schema/0.4.1/Turbine/BladedControl/MeasuredSignalProperties/SignalPropertiesLength/TransducerFaultsLength/TransducerFaultsLength.json
Not supported yet
: booleanApplyOnlyToFirst
: numberMiscalibrationOffset
: booleanInverseInstallation
: number (s)FailTime
: string =FaultType
None
|Noise
|ToConstant
|ConstantOffset
|GrowingOffset
|HarmonicOffset
: numberNoiseMultiplier
: numberFailureValue
: numberFailureValueRampRate
: numberConstantOffset
: numberGrowingOffset
: numberMagnitude
: number (s)Period
: number (m)MiscalibrationOffset
: number (m)FailureValue
: number (m/s)FailureValueRampRate
: number (m)ConstantOffset
: number (m/s)GrowingOffset
: number (m)Magnitude
Properties
ApplyOnlyToFirst
: boolean, optionalcoming soon
If true, the fault will be aplied only to the first instance of this transducer. If false, all sensors of this type will fail identically.
default = True
MiscalibrationOffset
: number, optionalcoming soon
A constant value added to the sensor's output - for example, if the sensor had been incorrectly installed or poorly calibrated.
default = 0.0
InverseInstallation
: boolean, optionalcoming soon
Whether the sensor was installed in reverse, resulting in its outputs being multiplied by -1.0.
default = False
FailTime
: number (s), optionalcoming soon
The time at which any time-dependent failure occurs. This will be from the beginning of the simulation, and not from the start of logging. Please ensure that this time will equate to a period which is being clearly logged.
default = 0.0
FaultType
: string, optionalcoming soon
What fault occurs at a specified time in the simulation.
default = None
NoiseMultiplier
: number, optionalcoming soon
The factor by which the noise on the signal increases (or decreases) by.
default = 1.0
FailureValue
: number, optionalcoming soon
The value which the sensor reverts to in the case of failure.
default = 0.0
FailureValueRampRate
: number, optionalcoming soon
The rate at which the signal reverts to its fail value. A rate of 0.0 represents an instantaneous step change to the fail value.
default = 0.0
ConstantOffset
: number, optionalcoming soon
The value by which the signal is offset by.
default = 0.0
GrowingOffset
: number, optionalcoming soon
The rate at which the signal is deviating from its calibrated value.
default = 0.0
Magnitude
: number, optionalcoming soon
The greatest magnitude of the harmonic interference from the 'true' value.
default = 0.0
Period
: number (s), optionalcoming soon
The time period of the full sinusoidal interference pattern.
default = 1.0
MiscalibrationOffset
: number (m), optionalcoming soon
A constant value added to the sensor's output - for example, if the sensor had been incorrectly installed or poorly calibrated.
default = 0.0
FailureValue
: number (m), optionalcoming soon
The value which the sensor reverts to in the case of failure.
default = 0.0
FailureValueRampRate
: number (m/s), optionalcoming soon
The rate at which the signal reverts to its fail value. A rate of 0.0 represents an instantaneous step change to the fail value.
default = 0.0
ConstantOffset
: number (m), optionalcoming soon
The value by which the signal is offset by.
default = 0.0
GrowingOffset
: number (m/s), optionalcoming soon
The rate at which the signal is deviating from its calibrated value.
default = 0.0
Magnitude
: number (m), optionalcoming soon
The greatest magnitude of the harmonic interference from the 'true' value.
default = 0.0